What makes this a fair comparison?
Set the inverter side to its average input during a representative session. For the fixed-speed side, use rated input and a realistic compressor on-time. Product labels alone cannot predict weather, insulation, room size, or thermostat behavior.
A calculation you can check
Imagine an inverter averaging 1.2 kW for five equivalent full-power hours: it uses 6.0 kWh. A fixed-speed unit drawing 1.9 kW while its compressor is on for 3.2 hours uses 6.08 kWh. These illustrative sessions are nearly equal even though their instantaneous inputs differ. Enter measured session energy or realistic on-time for each side instead of assuming the lower printed wattage always wins.
Before trusting the difference
- Use air conditioners sized for the same room and comparable cooling output.
- Compare the same outdoor conditions, thermostat setting and number of hours.
- Include purchase and maintenance costs only in a separate replacement decision.
Wattwise reports energy and operating cost only. Purchase price, capacity, comfort, maintenance, expected life, and repairability belong in a replacement-payback scenario.